Component contract
1. Job and envelope
- Function and observable behavior:
- Component family and why:
- Input/output quantities and units:
- Minimum / nominal / maximum / transient / fault:
- Supply rails, frequency, duty cycle, ambient, enclosure, lifetime:
- Acceptance criteria:
2. Identity and evidence
- Manufacturer and exact ordering code/package/revision:
- Datasheet and application-note URLs:
- Schematic, pinout, exposed pad, polarity, assembly constraints:
- Guaranteed values versus typical curves:
- Board/SoC schematic and firmware assumptions, if attached:
- Unknowns and evidence owner:
3. Margins and calculations
| Requirement | Equation/assumption | Corner | Result | Margin | Evidence |
|---|---|---|---|---|---|
- Tolerance, drift, noise, leakage, loading:
- Dissipation, thermal path, SOA/transient:
- Protection energy and clamp limits:
- Guaranteed / estimated / measured classification:
- Controlling corner and model-validity range:
- Observed fact:
- Inference supported by the fact:
Completed example
| Requirement | Equation/assumption | Corner | Result | Margin | Evidence |
|---|---|---|---|---|---|
| actuator conduction | P=I²R, hot guaranteed RDS(on) |
0.42 A steady, hot | 32 mW | below thermal budget | datasheet condition + measured rail |
The example is screening evidence only; startup linear-mode SOA and clamp waveforms remain separate requirements.
4. Interface and failure contract
- Logic thresholds, impedance, timing, power-up/down:
- Driver, pull resistor, clamp, flyback, snubber, fuse/current limit:
- Ground/isolation, creepage/clearance:
- Open, short, reversed, disconnected, brownout behavior:
5. Verification
- Instruments, fixtures, raw-data location:
- Normal, corner, reset/power-cycle, and fault tests:
- Temperature/supply/load corners:
- Calibration and diagnostic checks:
- Pass/fail evidence and unresolved risks: