Sensor calibration plan

Device and signal chain

  • Exact sensor, revision, package/module, output class:
  • Stimulus/input units and engineering-output units:
  • Excitation, reference, conditioning, ADC, sample rate, and filters:
  • Installation, fixture, orientation, cable, and environmental limits:

Reference conditions

  • Standards and traceability:
  • Reference points and uncertainty:
  • Temperature, supply, warm-up, and stabilization:
  • Instrument IDs, ranges, resolution, and calibration status:

Procedure

Point Applied reference (units) Raw output (units) Repeats Temperature (units) Supply (units)
  • Randomize or repeat order where drift could bias the fit:
  • Record warm-up, settling, overrange, disconnect, and recovery:
  • Preserve raw data and metadata before fitting:

Model and acceptance

  • Fit form and coefficient units:
  • Held-out validation points:
  • Residual, repeatability, hysteresis, drift, and noise limits:
  • Valid range and out-of-range behavior:
  • Coefficient storage, version, validity flag, and recalibration trigger:
  • Valid fit range in input/temperature units:
  • Invalid, disconnected, saturated, and out-of-range row:

Release evidence

  • Independent repeat and thermal/supply check:
  • Installation-specific verification:
  • Fault and diagnostic checks:
  • Raw-data path and report link:
  • Approver, date, and unresolved limitations: